top of page

Autoclave (Vertical) - Microprocessor control with reliable safety functions guarantees optimum sterilization temperature.

Autoclave - Vertical

Performance

  • Microprocessor controller and temperature calibration function allows for high precision temperature control.
    - Sterilization temperature at 110 to 123°C
    - Melting* temperature at 60 to 100°C
    * Liquefaction of coagulated agar media.
  • Automatic sterilization system for unattended operation.
    - Heating > Check safe > Sterilization > Sterilization safe > Exhausting > End
  • Convenient operation modes for various uses.
    - Standard modes and program modes are listed in detail as below tables.
  • Temperature calibration function.

Convenience

  • Conveniently monitored by an independent control display, sterilization process display, and pressure gauge.
    - VFD for visualization of temp, pressure(optional), timer, warning alert checks.
    - LED lamps for sterilization process check.
    - Easy pressure check with the standard gauge attached to the front.
  • Vertical type autoclaves which allow for top loading are suitable for high volume sterilization.
    - Baskets are stackable two high or even more levels, which secure inside the chamber space requirements.
  • Low-maintenance
    - The chamber is constructed of stainless steel which is superiorly resistant to corrosion.
    - Easy to replace silicone gasket.
  • Convenient documentation with the optional data recorder.
    - Dot type recorder(6 point) allows for precise documentation.

Safety

  • Mechanical safety devices
    - Over current protection.
    - Over temperature protection by automatic power cutoff.
    - Over pressure protection by automatic and manual safety valve.
  • Safety warning systems
    - Over temperature warning.
    - Low temperature warning.
    - Low water level warning.
    - Low heat warning if the temperature does not reach the sterilization or melting temperature.
    - Sterilization fail warning if the operation is unexpectedly stopped during sterilization process.
  • Slide opening door with plastic cover of low thermal conductivity prevents burns from the contact.

Address :
Sagix Solutions India 
No. 225, 11th cross,
BHCS, Banashankari 5th Stage
Bengaluru - 560061

 

Email Us :
sales@sagixsolutions.com
ssi-blr@sagixsolutions.com
customersupport@sagixsolutions.com

marketing@sagixsolutions.com

Contact Us :

Head Office
+91 9845410401
+91 9035174787

 

Hyderabad & Chennai 

Service Engineer 

+91 9606930605




 

Follow us on 

  • LinkedIn
  • Facebook

© 2023 by Sagix Solutions India. All Rights Reserved.

bottom of page